Table 3 The simulation parameters for multiple wake-up radios [12, 14, 15].

From: High sensitivity wake-up radio using spreading codes: design, evaluation, and applications

Wake-up radio

Parameter

Value

Units

All

Number of neighbors (N)

10

nodes

 

Number of wake-up radios (Nwur)

5

nodes

 

Wake-up packet length (Lwurp)

40

symbols

 

Wake-up address length (Lwurp_address)

16

symbols

 

Wake-up information length (Lwurinf)

24

symbols

 

Data radio supply voltage (Vccd)

3.3

V

 

Data radio transmit current (Itd)

25

mA

 

Data radio receive current (Ird)

9.2

mA

 

Data radio sending message time (Tmsg)

50.8

ms

 

Data radio sending node ID time (Tid)

1.18

ms

This work

Supply voltage (Vccwur)

3.3

V

 

Receive current (Iwur)

9.5

mA

 

Data rate (Rwur)

370

bit/s

 

Wake-up time from shut down (Tstwur)

1.1

ms

 

Symbol error rate at -114 dBm (SERwurl)

0.1

%

 

Symbol error rate at -122 dBm (SERwurh)

1

%

[15]

Data rate (Rd)

20

kbit/s

 

Wake-up time from shut down (Tstd)

380

μs

 

Symbol error rate (SERd)

0.1

%

[12]

Receive power (Pruif)

52

μW

 

Data rate (Ruif)

100

kbit/s

 

Wake-up time from shut down (Tstuif)

0

μs

 

Bit error rate (BERuif)

0.1

%

[14]

Receive power (Prulp)

500

μW

 

Data rate (Rulp)

100

kbit/s

 

Wake-up time from shut down (Tstulp)

5.24

μs

 

Bit error rate (BERulp)

0.1

%