Table 3 The average experimental results

From: Design and implementation of a distributed fall detection system based on wireless sensor networks

  Fall event Normal event
System: SensFall   
   Ground truth # 40 160
   Detected as fall event (rate) (%) 86.5 2.03
   Detected as normal event (rate) (%) 13.5 97.97
System: SIMBAD[26]   
   Ground truth # 14 30
   Detected as fall event (rate) (%) 35.7 3.3
   Detected as normal event (rate) (%) 64.3 96.7
System: proposed in[27]   
   Ground truth # 40 200
   Detected as fall event (rate) (%) 92.5 6.3
   Detected as normal event (rate) (%) 7.5 93.7