From: Automated uplink power control optimization in LTE-Advanced relay networks
Metric | Method | PC Scheme | P0(dBm) | Pmax(dBm) | ||||
---|---|---|---|---|---|---|---|---|
Direct link | Access link | Relay link | MUEs | RUEs | RNs | |||
NA | Manual optimization | FPC (α = 0.6) | −51 | −61 | −55 | 23 | 23 | 30 |
FCPC (α = 1.0) | −95 | −101 | −83 | 23 | 23 | 30 | ||
Γ5% | Taguchi’s method | FPC (α = 0.6) | −51 | −68 | −57 | 23 | 23 | 30 |
FCPC (α = 1.0) | −90 | −102 | −85 | 23 | 23 | 30 | ||
Simulated annealing | FPC (α = 0.6) | −53 | −71 | −71 | 23 | 23 | 30 | |
FCPC (α = 1.0) | −91 | −102 | −103 | 23 | 23 | 30 | ||
ΓHM | Taguchi’s method | FPC (α = 0.6) | −55 | −72 | −54 | 23 | 23 | 30 |
FCPC (α = 1.0) | −95 | −107 | −85 | 23 | 23 | 30 | ||
Simulated annealing | FPC (α = 0.6) | −55 | −72 | −50 | 23 | 23 | 30 | |
FCPC (α = 1.0) | −95 | −108 | −85 | 23 | 23 | 30 |