Skip to main content

Table 5 Parameter configurations for joint P 0 optimization in urban scenario

From: Automated uplink power control optimization in LTE-Advanced relay networks

Metric

Method

PC Scheme

P0(dBm)

Pmax(dBm)

Direct link

Access link

Relay link

MUEs

RUEs

RNs

NA

Manual optimization

FPC (α = 0.6)

−51

−61

−55

23

23

30

FCPC (α = 1.0)

−95

−101

−83

23

23

30

Γ5%

Taguchi’s method

FPC (α = 0.6)

−51

−68

−57

23

23

30

FCPC (α = 1.0)

−90

−102

−85

23

23

30

Simulated annealing

FPC (α = 0.6)

−53

−71

−71

23

23

30

FCPC (α = 1.0)

−91

−102

−103

23

23

30

ΓHM

Taguchi’s method

FPC (α = 0.6)

−55

−72

−54

23

23

30

FCPC (α = 1.0)

−95

−107

−85

23

23

30

Simulated annealing

FPC (α = 0.6)

−55

−72

−50

23

23

30

FCPC (α = 1.0)

−95

−108

−85

23

23

30