From: Dynamic base station planning with power adaptation for green wireless cellular networks
Parameter | Value |
---|---|
Coverage area | 5×5km2 |
Number of BSs | 200 |
Number of UCs | 10,000 |
Chunk size | 100 users |
BS location std. dev. | 1,000 m |
User location std. dev. | 100 m |
MIBD | 150 m |
BS core power | 150 W |
Number of PLs | 3 |
BS transmission PLs | 30, 90, and 270 W |
BS coverage distances | 300, 520, and 900 m |
BS capacity | 66 Erlang |
Max. prob. of blocking | 10-2 |
Average call duration | 30 s |
Average call arrival rate | 10 calls/day/user |
Number of time slots within a day | 24 |
Min. acceptable coverage ratio | 99% |
Penalty of a BS switch | 0, 75, 300, and 1,500 |