Table 2 System parameters

From: Scalable HetNet interference management and the impact of limited channel state information

Parameters

Symbols

Values

Number of macrocells

M

7

Sectors per macrocell

S

3

Inter macrocell distance

 

500 m

Macrocell radius

 

150 m

Macro users per sector

X m

20

Macro transmit Power

 

46 dBm

Number of picocells

P

5

Picocell radius

 

20 m

Pico users per sector

X p

4

Pico transmit Power

 

20 dBm

Number of femtocells

F

10

Femtocell radius

 

10 m

Femto users per sector

X f

2

Femto transmit power

 

10 dBm

System bandwidth

 

20 MHz

Available resource blocks

 

100

Carrier frequency

 

2.1 Ghz

Propagation model

 

WINNER II model [24]

Internal base station scheduler

 

Hungarian scheduler

Antenna configuration

 

SISO

Traffic model

 

Full buffer

Minimal throughput requested

th

1 Mbps