Table 3 Comparison between the sensor’s results and the analysis of fracture

From: Monitoring fatigue cracks of a metal structure using an eddy current sensor

Crack length (mm)

Analysis of fracture

Monitoring result

Error (%)

Average error

Standard deviation

Initiation (0.1)

25,300

27,800

9.88

4.61 %

0.0364

1

34,400

35,090

2.00

2

36,980

36,100

2.37

3

38,660

37,020

4.20