Table 1 Simulation components

From: Integrating energy efficiency analysis of massive MIMO-based C-RAN

Parameters Value
Antenna number per RRH 100
RRH number 10
Machine room 480 W
Number of UE per BS area 20
Mean transmission rate per UE 200 MHz
Circuit power of per RF chain \(P_{j}^{\text {RF}}\) 160 mW
Constant circuit power \({P_{j}^{c}}\) 160.8 W
PA efficiency η 35%
Power of antenna \({P_{j}^{k}}\) 37 dBm