Skip to main content

Table 1 The relevant parameters of the waveform simulator

From: Nonlinear self-interference cancellation in MIMO full-duplex transceivers under crosstalk

Parameter

Value

Bandwidth

20 MHz

Sampling frequency

122.88 MHz

Number of TX/RX antennas

2/2

PA gain

27 dB

PA IIP3

13 dBm

Level of TX crosstalk before the PAs

−10 dB/varied

Level of TX crosstalk after the PAs

−10 dB

Receiver noise floor

−96.9 dBm

Phase noise characteristics

See Fig. 5

Transmit power

25 dBm/varied

SI channel length

20 taps

Antenna attenuation

40 dB

RF cancellation

30 dB

IRR (TX/RX)

25 dB

ADC bits

12

Parameter estimation sample size (N)

30,000/varied

Parameter estimation sample size for PCA

10,000

Nonlinearity order of the canceller (P)

5

Number of pre-cursor taps (M 1)

10

Number of post-cursor taps (M 2)

20