Skip to main content

Table 5 Timing input for the process validation calculations

From: Smart container monitoring using custom-made WSN technology: from business case to prototype

Timing (unit)

UMTS connection

15

s

GPS position fix

90

s

802.15.4 duty cycle (active)

0.01

%

802.15.4 duty cycle (standby)

0.1

%

STP/REST transmitting period

300

s

STP/REST gateway search

60

s

STP/REST gateway setup

60

s

STP/REST report collection

120

s

STP/REST report ack

60

s

STP report interval min

3600

s

STP report interval max

64,800

s

REST report interval

86,400

s

SVE check interval

43,200

s

SVE UMTS search

300

s

MCU active

200

s

MCU standby

100

s

MCU LPM

X−300

s