Skip to main content

Table 2 Single damping oil film, liquid membrane effects on spindle amplitude

From: Research on fine boring simulation based on squeezed liquid film damper

Gap/mm

Width/mm

Amplitude/μm

Oil film

Non-oil film

Amplitude reduce

liquid film

Non-liquid film

Amplitude reduce

0.05

40

96

124

28

104

124

20

60

85

118

33

95

118

23

80

82

109

27

88

109

21

100

76

105

29

82

105

23

120

71

106

35

82

106

24

0.10

40

78

120

42

96

120

24

60

73

116

43

86

116

20

80

70

109

39

85

109

24

100

64

104

40

84

104

20

120

63

103

40

81

103

22

0.15

40

89

118

29

106

118

12

60

83

112

29

101

112

11

80

84

115

31

97

115

18

100

75

98

23

88

98

10

120

71

92

21

88

92

4