From: A novel torque sensor based on the angle of magnetization vector
Torque (Nm) | First measured data (V) | Second measured data (V) | Third measured data (V) | Fourth measured data (V) | Fifth measured data (V) | Sixth measured data (V) | Repeatability (%) |
---|---|---|---|---|---|---|---|
9.71 | 7.80 | 7.81 | 7.86 | 7.80 | 7.80 | 7.80 | 2.40 |
19.02 | 7.65 | 7.70 | 7.67 | 7.67 | 7.65 | 7.65 | 1.97 |
28.32 | 7.43 | 7.47 | 7.48 | 7.53 | 7.45 | 7.48 | 3.39 |
37.59 | 7.24 | 7.24 | 7.28 | 7.36 | 7.25 | 7.25 | 4.65 |
46.88 | 7.11 | 7.10 | 7.10 | 7.16 | 7.10 | 7.10 | 2.40 |
56.13 | 6.96 | 6.92 | 6.95 | 7.00 | 6.95 | 6.96 | 2.58 |
65.48 | 6.82 | 6.80 | 6.87 | 6.82 | 6.82 | 6.84 | 2.40 |
74.76 | 6.68 | 6.64 | 6.72 | 6.72 | 6.68 | 6.68 | 3.01 |
84.05 | 6.52 | 6.50 | 6.53 | 6.60 | 6.54 | 6.54 | 3.37 |
93.35 | 6.32 | 6.35 | 6.38 | 6.40 | 6.35 | 6.38 | 2.88 |