Table 1 Network parameters

From: A low redundancy data collection scheme to maximize lifetime using matrix completion technique

Parameter

Value

Value

T start

The time of start-up

5 10−6s

η

The drain efficiency of the amplifier

0.35

k

The exponent order

3

G 1

The gain factor

103

M 1

The link margin

104

P circuit

The power of circuit

140.7 mW

P syn

The power of frequency synthesizer

50 mW

σ 2

The AWGN power spectral density

3.981 10−21

B

The channel bandwidth

104

L

The number of bits in a data packet

103

N f

The receiver noise figure

10