Skip to main content

Table 7 Simulation parameters for the calibration

From: Uplink coverage enhancements for extremely large-cell sites

Parameter

Value

Antenna at BS

\({M\times N\times P=8\times 4\times 2}\)

Antenna at UE

\({M\times N\times P=1\times 2\times 2}\)

Path loss model

RMa-LMLC as per [15]

Fast-fading model

RMa as per 3GPP TR 38.901 [27]

Inter-site distance

6 km

System bandwidth

10 MHz

User density

10 per sector

User distribution

40% indoor 40% outdoor 20% outdoor in-car

Mechanical/electrical tilt

\(90^\circ\) in GCS/\(92^\circ\) in LCS

BS/UE height

35 m/1.5 m

BS/UE transmit power (\({P_{tx}}\))

46 dBm/23 dBm

BS/UE antenna gain

8 dBi/0 dBi

BS/UE noise figure

5 dB/7 dB

Interference modeling

Explicit

Thermal noise

\(-\)174 dBm/Hz

Sector boresight

30/150/270 degrees

User attachment

Based on RSRP

General parameters

Parameters not mentioned explicitly are as per [28]