Skip to main content

Table 1 Training and test error comparison of coarse model, dynamic Neuro-SM model, and the proposed general Neuro-SM model after combined DC, S parameter, and HB training

From: A general neuro-space mapping technique for microwave device modeling

Model type

Training/test error

Training/test error

20 hidden neurons

30 hidden neurons

Coarse model

38.12%/38.53%

38.12%/38.53%

Dynamic Neuro-SM (N v  = 5)

3.34%/3.59%

3.17%/3.44%

Dynamic Neuro-SM (N v  = 7)

3.09%/3.28%

2.71%/2.96%

General Neuro-SM (N v  = 3, N c  = 3)

3.25%/3.30%

3.05%/3.27%

General Neuro-SM (N v  = 5, N c  = 5)

1.64%/1.77%

1.50%/1.69%